lf

LF42

LF42 Pressure Switch

ModelLF42HLF42L
MediumWaterWater
Pressure set rangeCut-off pressure: 2.5bar±0.5barCut-in pressure: ≤0.1bar
Cut-in pressure: 1.5bar ±0.5barCut-off pressure: ≥0.2bar
Proof pressure18bar18bar
Durability40,000 cycles40,000 cycles
Working temperature5°C ~ 45°C5°C ~ 45°C
Switch typeMicroswitch – normally closedMicroswitch – normally open
Electrical ratingVoltage: 250VAC, Current: 16AVoltage: 250VAC, Current: 16A
Terminal4.8 x 0.8 mm blade4.8 x 0.8mm blade
Connector6mm quick connector6mm quick connector

LF42 series pressure switch is used in water supply pressure protection of water inlet. This series includes two models LF42H (high-pressure protection) and LF42L (low-pressure protection).

LF42H is the high-pressure protection switch model. If the pressure of the pressure vessel transferred reaches the setting value while the vessel is fully filled with water, the switch will cut off the circuit to make the pump stop. So the pump will not be damaged.

LF42L is the low-pressure protection switch. If the pressure of the water inlet is lower than the set value, RO will not work and keep dewatering, then the switch will cut off the circuit to make the pump stop. It can prevent the booster pump from continuing to work without water which may lead to damage to the circuit. If the pressure of the water inlet returns to the lowest set volume, the pump will work again.