lf

150W Type YSI-150

Rated Power: 150W
Input: 90-264V AC, 50 / 60Hz

With battery backup optional

Protection: Short Circuit, OCP, OVP
Output: 5-48V

Model:YSI-1001200YSI-1201200YSI-1501000YSI-2000750YSI-2500600YSI-4800300
DC Voltage:10V12V15V20V25V48V
Rated Current:12A12A10A7.5A6A3A
Current Range:0-12A0-12A0-10A0-7.5A0-6A0-3A
Rated Power:120W144W150W150W150W144W
Ripple & Noise(max.):100mVp-p120mVp-p200mVp-p200mVp-p250mVp-p480mVp-p
Voltage Tolerance:±5%±5%±5%±5%±5%±5%
Line Regulation:±3%±3%±3%±3%±3%±3%
Load Regulation:±5%±5%±5%±5%±5%±5%
Setup,Rise,Hold up time:3 second max./40 MS max./5 MS max. at 100VAC input and output max. load.
Model:YSI-150
Power:150W max.
Input:115/230VAC 50/60Hz
Output Voltage:5-48V
Output Current:0.01-12A
Input current:2.5A/1.5A max.
Inrush Current:80 Amps max. at 240VAC/50Hz,full load
Leakage Current:0.75mA Max. at 240VAC input
Protections:Short Circuit /Over Current /Over Voltage
Short Circuit Protection (SCP):Protection to Zero Voltage
Over Voltage Protection (OVP):≤Vout*150%
Over Current Protection (OCP):110%-180%
Working TEMP.:-20°C-50°C
Working Humidity:5%-90% RH non-condensing
Storage TEMP.,Humidity and altitude:-40℃ ~+70°C ambient temperature and a 5% to 95% relative humidity range throughout an altitude range of -60 meters to +5000 meters AMSL.
Certificates and approvals:CE,EMC,FCC,CCC,RoHS,REACH
EMI EMISSION:Radiation Test&Conduction Test: EN 55022/FCC Part 15
Harmonic Test : EN 61000-3-2
Flicker Test : EN 61000-3-3
EMS IMMUNITY:ESD  Test:EN 61000-4-2
RS    Test:EN 61000-4-3
EFT   Test:EN 61000-4-4
Surge Test:EN 61000-4-5
CS     Test:EN 61000-4-6
DIP    Test:EN 61000-4-11
MTBF:100000 hours minimum at full load at 25℃ ambient
Life:3-5 years alternative
Dimension:160*99*37mm
Weight:450g
Packing:20PCS/CTN,34.5*24.5*22.5cm