lf

20W Type YSI-20

Rated Power: 25W
Input: 90-264V AC, 50 / 60Hz
With battery backup optional
Protection: Short Circuit, OCP, OVP
Output: 5-48V

Model:YSI-0500400YSI-1200160YSI-1500133YSI-2000100YSI-3600055
DC Voltage:5V12V15V20V36V
Rated Current:4A1.6A1.33A1.0A0.55A
Current Range:0-4A0-1.6A0-1.33A0-1.0A0-0.55A
Rated Power:20W19.2W20W20W20W
Ripple & Noise(max.):100mVp-p120mVp-p150mVp-p200mVp-p360mVp-p
Voltage Tolerance:±5%±5%±5%±5%±5%
Line Regulation:±3%±3%±3%±3%±3%
Load Regulation:±5%±5%±5%±5%±5%
Setup,Rise,Hold up time:3 second max./40 MS max./5 MS max. at 100VAC input and output max. load.
Model:YSI-20
Power:20W max.
Input:110-240VAC 50/60Hz
Output Voltage:5-36V
Output Current:0.01-4A
Input current:0.5A max.
Inrush Current:Cold start 45A. at 240VAC/50Hz,full load
Leakage Current:2mA max. at 240VAC input
Protections:Short Circuit /Over Current /Over Voltage
Short Circuit Protection (SCP):Protection to Zero Voltage
Over Voltage Protection (OVP):≤Vout*150%
Over Current Protection (OCP):110%-180%
Working TEMP.:-20°C-60°C
Working Humidity:20%-90% RH non-condensing
Storage TEMP.,Humidity and altitude:-40℃ ~+70°C ambient temperature and a 5% to 95% relative humidity range throughout an altitude range of -60 meters to +5000 meters AMSL.
Certificates and approvals:CE,EMC,FCC,CCC,RoHS,REACH
EMI EMISSION:Radiation Test&Conduction Test: EN 55022/FCC Part 15
Harmonic Test : EN 61000-3-2
Flicker Test : EN 61000-3-3
SAFETY STANDARDS:EN 60950-1:2006+A11:2009+A1:2010+A12:2011
MTBF:100000 hours minimum at full load at 25℃ ambient
Life:3-5 years alternative
Dimension:98*58*37mm(L*W*H)
Weight:1380g