lf

250W Type YSI-250

Rated Power: 240W
Input: 90-264V AC, 50 / 60Hz
Protection: Short Circuit, OCP, OVP
Output: 5-48V
Inrush Current: 65 Amps max. at 230VAC/50Hz, full load

Model:YSI-1002000YSI-1202000YSI-1501600YSI-2001250YSI-2501000YSI-4800500
DC Voltage:10V12V15V20V25V48V
Rated Current:20A20A16A12.5A10A5A
Current Range:0-20A0-20A0-16A0-12.5A0-10A0-5A
Rated Power:200W240W240W250W250W240W
Ripple & Noise(max.):100mVp-p120mVp-p200mVp-p200mVp-p250mVp-p480mVp-p
Voltage Tolerance:±5%±5%±5%±5%±5%±5%
Line Regulation:±3%±3%±3%±3%±3%±3%
Load Regulation:±5%±5%±5%±5%±5%±5%
Setup,Rise,Hold up time:3 second max./40 MS max./5 MS max. at 100VAC input and output max. load.
Model:YSI-240
Power:250W max.
Input:115/230VAC 50/60Hz
Output Voltage:5-48V
Output Current:0.01-20A
Input current:3.5A/2.5A max.
Inrush Current:250 Amps max. at 240VAC/50Hz,full load
Leakage Current:3.5mA Max. at 240VAC input
Protections:Short Circuit /Over Current /Over Voltage
Short Circuit Protection (SCP):Protection to Zero Voltage
Over Voltage Protection (OVP):≤Vout*150%
Over Current Protection (OCP):110%-180%
Working TEMP.:-20°C-50°C
Working Humidity:5%-90% RH non-condensing
Storage TEMP.,Humidity and altitude:-40℃ ~+70°C ambient temperature and a 5% to 95% relative humidity range throughout an altitude range of -60 meters to +5000 meters AMSL.
Certificates and approvals:CE,EMC,FCC,CCC,RoHS,REACH
EMI EMISSION:Radiation Test&Conduction Test: EN 55022/FCC Part 15
Harmonic Test : EN 61000-3-2
Flicker Test : EN 61000-3-3
EMS IMMUNITY:ESD  Test:EN 61000-4-2
RS    Test:EN 61000-4-3
EFT   Test:EN 61000-4-4
Surge Test:EN 61000-4-5
CS     Test:EN 61000-4-6
DIP    Test:EN 61000-4-11
MTBF:100000 hours minimum at full load at 25℃ ambient
Life:3-5 years alternative
Dimension:200*109*50mm
Weight:910g
Packing:10PCS/CTN,29.5*25*23cm