lf

30W Type YSL36L

Input:220-240VAC 50Hz
Rated Power: 36W
Output Voltage: 12V/24V
Application: CCTV Camera, Monitoring System in Security field, Industrial Display Screen,LED strip etc.

Model:YSL30L-12YSL30L-24YSL30L-36YSL30L-48
Dimming type
Rated Voltage:12V24V36V48V
Current Range:0.1-2.5A0.1-1.25A0.1-0.833A0.1-0.625A
Rated Power:30W30W30W30W
Ripple & Noise(max.):<1%<1%<1%<1%
Voltage Tolerance:±5%±5%±5%±5%
Line Regulation:±3%±3%±3%±3%
Load Regulation:±5%±5%±5%±5%
Efficiency:88%88%88%88%
Setup,Rise time1 second max./40 MS max.
Model:YSL30L
Dimming Type
Power:30W max.
Input:100-240VAC 50/60Hz
Output Voltage:3-48V
Output Current:100MA-2.5A
Inrush Current:(浪涌电流)65 Amps max. at 230VAC/50Hz,full load
Leakage Current:2.5mA Max. at 264VAC input
No Load Power Consumption:<0.5W
Protections:Short Circuit /Over Current /Over Voltage/over temperature protection
Short Circuit Protection (SCP):Protection to Zero Voltage
Over Voltage Protection (OVP):≤Vout*150%
Over Current Protection (OCP):110%-180%
Working TEMP.:-20°C-50°C
Working Humidity:5%-90% RH non-condensing
Storage TEMP.,Humidity and altitude:-40℃~+70°C ambient temperature and a 5% to 95% relative humidity range throughout an altitude range of -60 meters to +5000 meters AMSL.
Certificates and approvals:CE,EMC,RoHS,REACH
EMI EMISSION:Conducted disturbance at mains terminals:EN 55015Radiation Test&Conduction Test: EN 55015Magnetic Emission:EN55015:2013
Harmonic Test : EN 61000-3-2
Voltage fluctuation and Flicker Test : EN 61000-3-3
EMS IMMUNITY:ESDTest:IEC 61000-4-2
RSTest:IEC 61000-4-3
EFT/B ImmunityTest:IEC61000-4-4
Surge Immunity :IEC61000-4-5
Conduted RF Immunity:IEC 61000-4-6
Power frequency magnetic field:IEC 61000-4-11Voltage dips and interruptions,100% reduction: IEC 61000-4-11Voltage dips and interruptions,30% reduction: IEC 61000-4-11
MTBF:100000 hours minimum at full load at 25℃ambient
Life:3-5 years alternative
Dimension:120*46*30mm
Weight:
Packing:100pcs/CTN54.5*27.5*22.5cm