lf

150W Desktop Type YS150

Model:YS150-1201100YS150-1500900YS150-2007000YS150-2406000YS150-3604160YS150-4803100
DC Voltage:12V15V20V24V36V48V
Rated Current:11A9A7A6A4.16A3.1A
Current Range:0-11A0-9A0-7A0-6A0-4.16A0-3.1A
Rated Power:132W135W140W144W150W150W
Ripple & Noise(max.):120mVp-p150mVp-p200mVp-p200mVp-p240mVp-p300mVp-p
Voltage Tolerance:±5%±5%±5%±5%±5%±5%
Line Regulation:±3%±3%±3%±3%±3%±3%
Load Regulation:±5%±5%±5%±5%±5%±5%
Efficiency:89%89%89%89%89%89%
Setup, Rise, Hold up time:1.5 secs max./40 MS max./15 MS max. at 115VAC input and output max. load.
PF>0.95  230V AC   FULL LOAD
HI-POT3000V AC  60S 5mA
Model:YS150
Power:200W max.
Input:100-240VAC, 50/60Hz
Output Voltage:12-48V
Output Current:0.1-11A
Input current:2A max.
Inrush Current:65 Amps max. at 230VAC/50Hz, full load
Leakage Current:0.25mA Max. at 264VAC input
Energy Efficiency Level VI :CoC 5 / DoE 6 / CEC VI
No Load Power Consumption :<0.15W
Protections:Short Circuit /Over Current /Over Voltage
Short Circuit Protection (SCP):Protection to Zero Voltage
Over Voltage Protection (OVP):≤Vout*150%
Over Current Protection (OCP):110%-180%
Working TEMP.:-20°C-50°C
Working Humidity:5%-90% RH non-condensing
Storage TEMP.,Humidity and altitude:-40℃ ~+70°C ambient temperature and a 5% to 95% relative humidity range throughout an altitude range of -60 meters to +5000 meters AMSL.
Input Plug: EU, US, UK, AU etc. type according to customer’s choice
Certificates and approvals:UL, GS, CE, EMC, SAA, FCC, CB, PSE, CCC, RoHS, REACH
EMI EMISSION:Radiation Test & Conduction Test: EN 55022/FCC Part 15
Harmonic Test: EN 61000-3-2
Flicker Test: EN 61000-3-3
EMS IMMUNITY:ESD  Test: EN 61000-4-2
RS    Test: EN 61000-4-3
EFT   Test: EN 61000-4-4
Surge Test: EN 61000-4-5
CS     Test: EN 61000-4-6
DIP    Test: EN 61000-4-11
MTBF:100000 hours minimum at full load at 25℃ ambient
Life:3-5 years alternative
Dimension:190*90*45mm
Weight:650g
Packing:20PCS/CTN, 42.5*42*20cm